Remaining life
Every app has a Remaining life tab: how long until an indicator reaches its limit, as an approximate range with the limit and its source, never a single date.
Open an exampleCAPMAC checks valves and loops, city water and buildings with checks that each passed a fair test. Real data comes first on this page; simulator results come after, labelled quietly.
Pick your equipmentEvery app has a Remaining life tab: how long until an indicator reaches its limit, as an approximate range with the limit and its source, never a single date.
Open an exampleEvery reading goes through checks that each passed a fair test before they may raise an alarm.
OpenPlain physics picture of pumps, chillers and valves; the confidence tier is shown on every verdict.
OpenPer-unit healthy levels worked out from your own history, no black box.
OpenRead-only link to your plant: OPC UA or a CSV upload.
OpenWe watch: Sticking, jams, leaking seats, plugged trim, wear.
22checks working
REAL
Real Bauer/SACAC loops: all 3 sticking loops flagged. Small sample; trial on your own records recommended. No licence stated: shown one-to-one only; do not copy or forward.
Open in the appWe watch: Air supply loss, miscalibrated travel, diaphragm leaks.
6checks working
OWN SIMULATED
Passed on our own simulated valves; no real or outside-simulator pass yet.
Open in the appWe watch: Oscillation, windup, saturation, manual mode, sluggish response, wrong set point.
24checks working
OWN SIMULATED
Sluggish-loop and hidden stick-slip checks passed fresh own-simulated tests; no real-data pass yet.
Open in the appWe watch: Night flow, bursts, meter drift, theft, repairs confirmed.
48checks working
REAL
Real data from Yorkshire Water: repairs confirmed 0.30 vs placebo 0.03 on one test, 0.30 vs 0.05 on the next. Alerts are tuned for a low false-alarm rate; trial on your own history recommended.
Open in the appWe watch: Which mains to renew first (the order is tested; a chance of breaking is not), surge, closed valves, pressure-reducing valves.
21checks working
REAL
Real data from City of Topeka: top 10 % of pipes hold 61.7 % of 478 breaks vs 52.3 % by material alone (latest test).
Open in the appWe watch: Vibration, bearings, curve, cavitation, short cycling.
54checks working
OWN SIMULATED
Passed our own simulated tests and held-out tests on simulated records; no real-plant pass yet.
Open in the appWe watch: Level balance, overflow, leakage, chlorine decay.
4checks working
OWN SIMULATED
Tank and chlorine checks pass on our own data.
Open in the appWe watch: Dampers, valves, filters, mixed air, stuck or spiking sensors.
8checks working
REAL
Narrow pass on real Korean office air handlers: injected sensor bias found, nothing false (9 of 19 stretches judged).
Open in the appWe watch: Stuck damper and airflow bias against the box's own normal level.
2new checks(new, tested on real data, not yet in the main count)
REAL
Real evening set (Figshare 27948192): 18 of 18 stuck dampers, 7 of 8 airflow bias, 1 false alarm in 234.
Open in the appWe watch: Leaking valves, filters, dampers, fan loss, zone sensor bias.
9checks working
OUTSIDE SIMULATOR
LBNL fan-coil open files: 4 of 4 faults, 0 false calls (easy by construction).
Open in the appWe watch: Fouling, undercharge, flow loss, staging, sensor bias.
26checks working
REAL OUTSIDE SIMULATOR
Real data from the FrostByte rig: all severe fault groups named right on rig data it had not seen, no healthy period alarmed. FrostByte (TH Wildau), CC BY-NC 4.0: shown one-to-one only; do not copy or forward. Outside simulator (LBNL plant): 9 of 10 aimed fault pairs found in each of two later tests, no false calls.
Open in the appWe watch: Approach, fan, blowdown, fill fouling, hunting loop.
14checks working
OWN SIMULATED
Passed our own simulated tests and held-out tests on simulated records.
Open in the appWe watch: Filters, coils, CRAH fans, HEPA, door, pressure.
20checks working
OWN SIMULATED
Passed our own simulated tests.
Open in the appWe watch: CRAH / CRAC filters, coils, fans, valves, air paths, supply air, free-cooling exchanger; a PUE-style energy view.
11checks working (8 also passed a held-out test)
HELD-OUT TEST, SIMULATED
Real data: none yet from a data centre. Passed held-out tests on simulated records.
Open Data centresWe watch: BMS points by AHU, VAV, fan-coil and chiller; schedule and override audit; simultaneous heating and cooling; set-point drift; trend-log quality.
7check groups
REAL
Real data from a VAV building and office air handlers. LBNL fan-coil lab files are an outside-simulator result, not real plant data. Read-only BACnet/IP connector.
Open Building automationWalk through a building, a data centre, a valve plant and a city water network with live check results on the equipment.
Building Data centre Valves WaterPut in your own prices and sizes; every figure is marked as an assumption you can change.
Open the calculatorHow your data is read, and how healthy levels are worked out, are explained on the Connect and Learn pages.
Connect Learn